    Sintrol S304

 

 

 

mg/m3 Ãâ·Â ´ÜÀ§ ¼³Á¤°¡´ÉÇÑ ¸ÕÁö¹èÃâ ÃøÁ¤±â

¸ÕÁö ¹ÐÁýÀÇ Àý´ë°ª ¼öÄ¡°¡ ÇÊ¿äÇÑ È°¿ëÀ» À§ÇØ, S304´Â mg/m3 »ç¿ëÀÚ Ãâ·Â ´ÜÀ§·Î ¼³Á¤µÉ ¼ö ÀÖ½À´Ï´Ù. ¼³Á¤ÀÌ µÈ´Ù¸é, ÀÌ ¸ð´ÏÅÍ´Â °øÀå ÀÛ¾÷ÀÚµéÀÌ °øÀåÀÇ ±¼¶ÒÀ̳ª ¹èÃⱸ¸¦ ÅëÇØ ¸ÕÁö°¡ Á¤È®È÷ ¾ó¸¶³ª Åë°úµÇ´ÂÁö ¾Ë ¼ö ÀÖ°ÔÇÕ´Ï´Ù.

S304´Â Ãß°¡ÀûÀ¸·Î 4-20mA ½ÅÈ£¿Í °øÀå¿¡¼­ ´õ¿í ÃÖÀûÈ­µÈ °øÁ¤Á¶°Çµé¿¡ »ç¿ëµÉ ¼ö ÀÖ´Â µÎ °³ÀÇ µ¶¸³ÀûÀÎ ¸±·¹À̸¦ °®Ãß°í ÀÖ½À´Ï´Ù.

Emissions monitor that can be calibrated to give mg/m3 output

 

For applications requiring absolute value measurements of dust concentrations, the S304 can be calibrated to give the user a mg/m3 output.  Once calibrated, this dust monitor helps plant operators know exactly how much dust is passing through the stack or outlet duct of their plant.

The S304 is additionally equipped with a 4-20mA signal and two independent alarm relays that can be used to further optimized process conditions in the plant.

 

     

 

 

S300 Series dust monitors
Measurement Objects Solid particles in gas flow
Particle Size 0.3µm or larger
Measurement Range From 0.1mg/m³ 
Measurement Principle Inductive Electrification
Protection Category IP65
Probe Length (total/measuring) 500mm/440mm, 750mm/690mm (optional),1000mm/940mm (optional), >1000mm on request
19.7" / 17.3", 29.5" / 27.2", 39.4" / 37.0" (optional), > 39.4" on request
Power Supply 115 VAC, 230 VAC or 24 VDC
Power Consumption DC model Max 3 W, AC model Max 8 W
Wiring Connections - Power Supply DIN PG11 cable gland
Wiring Connections - Output Signals DIN PG11 cable gland
Process Connection socket (38 mm OD), quick clamp (optional), flange (optional)
Output Signals - Two SPDT relays: 5A, 24V AC/DC
Range Set Up - Normal measuring range: automatic, based on average measured dust flow during setup procedure
- Extended measuring range: User selectable
Relay Alarm Settings - Automatic, set at factory: Based on average measured dust flow
- User selectable ranges
Offset Trim Automatic drift compensation
Signal Damping Time 0-300 s
Relay Delay Time 0-180 s

 

 
Process Conditions
Temperature Max 300°C, Max 700°C (optional)
Max 572 °F, Max 1292 °F (optional)
Pressure Max 200 kPa, Max 600 kPa (optional)
Max 43.5 PSI, Max 87 PSI (optional)
Gas Velocity Min 4m/s   ©¥   Min 13.1 ft/s
Humidity Max 95% RH (non-condensing)

 

 
Ambient Conditions
Temperature -20....+45°C and 60°C for 24 VDC
-4 to 113 °F and to 140 °F for 24 VDC
Humidity Max 95% RH (non-condensing)
Vibration Max 5 m/s²   ©¥   Max 16.4 ft/s2

 

 
Materials
Probe (wetted part) Stainless steel (AISI 316L)
Probe Coating (wetted part) PTFE Teflon (optional)
Process Connection (wetted part) Stainless steel (AISI 316L)
Probe Insulation  (wetted part) PEEK
Probe Sealing (wetted part) FPM Viton
Enclosure Aluminum alloy
Weight 2.3kg   ©¥   5.1 lb

 

 

Top   


    Á¦Ç° > ¹èÃâ ÃøÁ¤

    Products > Emissions Monitoring

    Sintrol S305

 

 

 

°ø½ÄÀûÀÎ ¹èÃâ ÃøÁ¤À» À§ÇÑ TUV ÀÎÁõ ±¼¶Ò ¸ÕÁö ÃøÁ¤±â

EN 14181 Ç¥ÁØÀ» ÁؼöÇÑ TUVÀÎÁõµÈ, S305 ¸ÕÁö ÃøÁ¤±â´Â °ø½ÄÀûÀÎ ¹èÃâ ÃøÁ¤¿¡ »ç¿ëÀÌ µË´Ï´Ù. ÷´Ü ¸ÕÁö ÃøÁ¤±â´Â Àü ¼¼°è¿¡ ¼ö ¸¹Àº °³ÀÎ »ç¼³ °øÀå¿¡¼­ ±¼¶Ò ¹èÃâ±â¿¡ »ç¿ëµÇ°í ÀÖ½À´Ï´Ù.

¿ì¸®ÀÇ µ¶Ã¢ÀûÀÎ Àü±âÀ¯µµ ¿ø¸®¸¦ ÀÌ¿ëÇÏ¿©, S305´Â Á¤ºÎ°¡ ¿ä±¸ÇÏ´Â ½Å·Ú¼ºÀ» °¡Á®¿À°í °øÀå ÀÛ¾÷ÀÚµéÀÌ ¸ÕÁöÃøÁ¤ ÀåÄ¡·ÎºÎÅÍ ±â´ëÇÏ´Â Æí¸®¼ºµµ °®Ãß¾ú½À´Ï´Ù. ÃÖ¼ÒÇÑÀÇ À¯Áö·Î, ÀÌ ÃøÁ¤±â´Â È®½ÇÇÏ°Ô Á¤ºÎÀÇ ±ÔÁ¦¿¡ ¸ÂÃß¾î ±¼¶Ò ¹èÃâ ¸ÕÁö¸¦ ÃøÁ¤ÇÒ Çʿ䰡 ÀÖ´Â °øÀå ÀÛ¾÷Àڵ鿡°Ô ÃÖÀûÀÇ ÇØ¹ýÀÔ´Ï´Ù.

TUV certified stack monitor for official emissions measurements

 

Certified by TUV to meet the EN 14181 standard, the S305 dust monitor is used for official emissions applications.  The state of the art dust monitor has been used in stack emissions for a number of state owned and private industrial applications around the world.

Utilizing our unique electric induction principle, the S305 brings the reliability the government requires and combines it with the convenience plant operators expect from a particulate measurement device. With minimal maintenance required, this is an optimal solution for plant operators needing to measure stack dust emissions for government control.

 

     

 

 

S300 Series dust monitors
Measurement Objects Solid particles in gas flow
Particle Size 0.3µm or larger
Measurement Range From 0.1mg/m³ 
Measurement Principle Inductive Electrification
Protection Category IP65
Probe Length (total/measuring) 500mm/440mm, 750mm/690mm (optional),1000mm/940mm (optional), >1000mm on request
19.7" / 17.3", 29.5" / 27.2", 39.4" / 37.0" (optional), > 39.4" on request
Power Supply 115 VAC, 230 VAC or 24 VDC
Power Consumption DC model Max 3 W, AC model Max 8 W
Wiring Connections - Power Supply DIN PG11 cable gland
Wiring Connections - Output Signals DIN PG11 cable gland
Process Connection socket (38 mm OD), quick clamp (optional), flange (optional)
Output Signals - Two SPDT relays: 5A, 24V AC/DC
Range Set Up - Normal measuring range: automatic, based on average measured dust flow during setup procedure
- Extended measuring range: User selectable
Relay Alarm Settings - Automatic, set at factory: Based on average measured dust flow
- User selectable ranges
Offset Trim Automatic drift compensation
Signal Damping Time 0-300 s
Relay Delay Time 0-180 s

 

 
Process Conditions
Temperature Max 300°C, Max 700°C (optional)
Max 572 °F, Max 1292 °F (optional)
Pressure Max 200 kPa, Max 600 kPa (optional)
Max 43.5 PSI, Max 87 PSI (optional)
Gas Velocity Min 4m/s   ©¥   Min 13.1 ft/s
Humidity Max 95% RH (non-condensing)

 

 
Ambient Conditions
Temperature -20....+45°C and 60°C for 24 VDC
-4 to 113 °F and to 140 °F for 24 VDC
Humidity Max 95% RH (non-condensing)
Vibration Max 5 m/s²   ©¥   Max 16.4 ft/s2

 

 
Materials
Probe (wetted part) Stainless steel (AISI 316L)
Probe Coating (wetted part) PTFE Teflon (optional)
Process Connection (wetted part) Stainless steel (AISI 316L)
Probe Insulation  (wetted part) PEEK
Probe Sealing (wetted part) FPM Viton
Enclosure Aluminum alloy
Weight 2.3kg   ©¥   5.1 lb

 

 